|
|
Model # |
Đơn giá (VND) |
Stock ? |
Manufacturer |
Min order |
RoHS status |
Seri |
Package |
Part Status |
Datasheet |
Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Add selected items to basket |
|
|
|
|
- immediate |
TDK-Lambda |
1 |
RoHS Compliant |
RWS-B (300W) |
Bulk |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 265 VAC | 48V | - | - | - | - | 6.3 A | 300W | ITE (Commercial) | 3 kV | 88% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 6.70" L x 4.02" W x 1.61" H (170.0mm x 102.0mm x 41.0mm) | CE | - | - | - |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
ENP-360 (360W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 90 ~ 264 VAC, 127 ~ 370 VDC | 27.6V | - | - | - | - | 13 A | 359W | ITE (Commercial) | 3 kV | 93% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Benchtop | 7.56" L x 7.01" W x 1.79" H (192.0mm x 178.0mm x 45.5mm) | CB, CE, cULus | - | - | - |
|
|
|
|
|
- immediate |
TDK-Lambda |
1 |
RoHS Compliant |
CUS100ME (100W) |
Bulk |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | 8.33 A | 100W | Household Appliances, ITE (Commercial), Medical | 4 kV | 94% | -20°C ~ 85°C (With Derating) | Universal Input | Chassis Mount | 4.57" L x 2.52" W x 1.52" H (116.0mm x 64.0mm x 38.5mm) | - | - | - | - |
|
|
|
|
|
- immediate |
EOS Power |
1 |
RoHS Compliant |
WLT150 (150W) |
Bulk |
Active |
Datasheet
|
Open Frame | 1 | 90 ~ 264 VAC, 120 ~ 390 VDC | 24V | - | - | - | - | - | 4.17 A | 100W (150W Forced Air) | ITE (Commercial) | 4.242 kV | 86% | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) | CB, CE, cUL, NEMKO, UL | - | - |
|
|
|
|
|
- immediate |
Traco Power |
1 |
ROHS3 Compliant |
TPI 100A (100W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 4.17 A | 100W | ITE (Commercial) | 3 kV | 92% | -40°C ~ 80°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.16" H (76.2mm x 50.8mm x 29.5mm) | CB, CE, cURus | - | - |
|
|
|
|
|
- immediate |
Traco Power |
1 |
ROHS3 Compliant |
TMM 24 (24W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 2 A | 24W | Industrial, ITE (Commercial), Medical | 4 kV | 83% | -40°C ~ 80°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | CB, CE, cULus, cURus | - | - |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
EPP-120S (120W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 80 ~ 264 VAC, 113 ~ 370 VDC | 12V | - | - | - | - | - | 9.5 A | 114W (142W Forced Air) | ITE (Commercial) | 4 kV | 91% | -30°C ~ 85°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.10" H (76.2mm x 50.8mm x 28.0mm) | CB, CE, cURus, EAC, TUV | - | - |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
RT-85 (85W) |
Box |
Active |
Datasheet
|
Enclosed | 3 | 88 ~ 264 VAC, 125 ~ 373 VDC | 5V | 12V | -12V | - | - | 8 A | 3.5 A | 500 mA | 88W | ITE (Commercial) | 3 kV | 76% | -25°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 6.26" L x 3.82" W x 1.50" H (159.0mm x 97.0mm x 38.0mm) | CB, CE, cURus, TUV | - |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
MPM-90 (90W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 80 ~ 264 VAC, 113 ~ 370 VDC | 24V | - | - | - | - | - | 3.75 A | 90W (99W Forced Air) | Household Appliances, Medical | 4 kV | 93% | -30°C ~ 80°C (With Derating) | - | Chassis Mount | 4.29" L x 2.05" W x 1.32" H (109.0mm x 52.0mm x 33.5mm) | CB, CE, cURus, EAC, TUV | - | - |
|
|
|
|
|
- immediate |
XP Power |
1 |
ROHS3 Compliant |
ECS (25W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | 2.08 A | 25W | ITE (Commercial), Medical | 4 kV | 90% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.95" H (76.2mm x 50.8mm x 24.2mm) | CB | 62368-1 | - | - |
|
|
|
|
|
- immediate |
CUI Inc. |
1 |
ROHS3 Compliant |
VOF-50B (50W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 4.2 A | 50W | ITE (Commercial) | 3 kV | 87% | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.05" H (101.6mm x 50.8mm x 26.6mm) | CB Scheme, CE, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 61000-3-2; 61000-3-3; 62368-1 | - |
|
|
|
|
|
- immediate |
Delta Electronics |
1 |
ROHS3 Compliant |
PMT (99W) |
Bulk |
Active |
Datasheet
|
Enclosed | 2 | 88 ~ 132 VAC, 176 ~ 264 VAC | 12V | 5V | - | - | - | 7 A | 3 A | 100W | ITE (Commercial) | 3 kV | 82% | -10°C ~ 70°C (With Derating) | Adjustable Output | Chassis Mount | 7.01" L x 3.82" W x 1.50" H (178.0mm x 97.0mm x 38.0mm) | CB, CCC, CE, cURus, TUVgs | - | - |
|
|
|
|
|
- immediate |
Cincon Electronics Co. LTD |
1 |
ROHS3 Compliant |
CFM40T (40W) |
Box |
Active |
Datasheet
|
Open Frame | 3 | 90 ~ 264 VAC | 5V | 12V | -12V | - | - | - | 3 A | 2 A | 300 mA | 43W | ITE (Commercial) | 4.242 kV | 78% | 0°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.13" H (101.6mm x 50.8mm x 28.6mm) | CE, cURus, FCC, TUV |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
RSP-100 (100W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | 4.2 A | 101W | ITE (Commercial) | 4 kV | 87% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 7.05" L x 3.90" W x 1.18" H (179.0mm x 99.0mm x 30.0mm) | CB, CCC, CE, cURus, TUV | - | - | - |
|
|
|
|
|
- immediate |
SL POWER / Advanced Energy |
1 |
RoHS Compliant |
GB60S (60W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 80 ~ 270 VAC | 24V | - | - | - | - | 2.5 A | 60W | ITE (Commercial) | 4 kV | 88% | -10°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.00" H (76.2mm x 50.8mm x 25.4mm) | CE | - | - | - |
|
|
|
|
|
- immediate |
CUI Inc. |
1 |
ROHS3 Compliant |
VOF-85B (85W) |
Box |
Active |
Datasheet
|
Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 3.55 A | 85W | ITE (Commercial) | 3 kV | 89% | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.6mm) | CB Scheme, CE, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 61000-3-2; 61000-3-3; 62368-1 | - |
|
|
|
|
|
- immediate |
MEAN WELL USA Inc. |
1 |
ROHS3 Compliant |
RSP-150 (150W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | 3.2 A | 154W | ITE (Commercial) | 4 kV | 90% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 7.83" L x 3.90" W x 1.18" H (199.0mm x 99.0mm x 30.0mm) | CB, CCC, CE, cURus, TUV | - | - | - |
|
|
|
|
|
- immediate |
Delta Electronics |
1 |
ROHS3 Compliant |
PMH (150W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | 6.25 A | 150W | Household Appliances, ITE (Commercial) | 4.5 kV | 91% | -30°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, Universal Input | Chassis Mount | 7.01" L x 3.82" W x 1.50" H (178.0mm x 97.0mm x 38.0mm) | CB, CE, cURus | - | - | - |
|
|
|
|
|
- immediate |
Traco Power |
1 |
ROHS3 Compliant |
TXL 025 (25W) |
Box |
Active |
Datasheet
|
Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 375 VDC | 24V | - | - | - | - | - | 1.1 A | 26W | ITE (Commercial) | 3 kV | 84% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 3.11" L x 2.01" W x 1.12" H (79.0mm x 51.1mm x 28.4mm) | CE, cURus | - | - |
|
|
|
|
|
- immediate |
TDK-Lambda |
1 |
RoHS Compliant |
ZWS30B (30W) |
Bulk |
Active |
Datasheet
|
Open Frame | 1 | 85 ~ 265 VAC | 24V | - | - | - | - | 1.3 A | 30W | ITE (Commercial) | 3 kV | 86% | -10°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, Universal Input | Chassis Mount | 5.24" L x 2.17" W x 1.02" H (133.0mm x 55.1mm x 25.9mm) | CE | - | - | - |
|